PART 890 ILLINOIS PLUMBING CODE : Sections Listing

TITLE 77: PUBLIC HEALTH
CHAPTER I: DEPARTMENT OF PUBLIC HEALTH
SUBCHAPTER r: WATER AND SEWAGE
PART 890 ILLINOIS PLUMBING CODE


SUBPART A: DEFINITIONS AND GENERAL PROVISIONS

SUBPART B: PLUMBING MATERIALS

SUBPART C: JOINTS AND CONNECTIONS

SUBPART D: TRAPS AND CLEANOUTS

SUBPART E: INTERCEPTORS - SEPARATORS AND BACKWATER VALVES

SUBPART F: PLUMBING FIXTURES

SUBPART G: HANGERS, ANCHORS AND SUPPORTS

SUBPART H: INDIRECT WASTE PIPING, SPECIAL WASTE

SUBPART I: WATER SUPPLY AND DISTRIBUTION

SUBPART J: DRAINAGE SYSTEM

SUBPART K: VENTS AND VENTING

SUBPART L: PLUMBING SYSTEMS/CORRECTIONAL FACILITIES

SUBPART M: INSPECTIONS, TESTS, MAINTENANCE AND ADMINISTRATION


  • Section 890.APPENDIX B Illustrations for Subpart A

  • Section 890.APPENDIX C Illustrations for Subpart C

  • Section 890.APPENDIX D Illustrations for Subpart D

  • Section 890.APPENDIX E Illustrations for Subpart E

  • Section 890.APPENDIX F Illustrations for Subpart F

  • Section 890.APPENDIX G Illustrations for Subpart G

  • Section 890.APPENDIX H Illustrations for Subpart H

  • Section 890.APPENDIX I Illustrations for Subpart I

  • Section 890.APPENDIX J Illustrations for Subpart J

  • Section 890.APPENDIX K Illustrations for Subpart K
  • AUTHORITY: Implementing and authorized by Section 35 of the Illinois Plumbing License Law [225 ILCS 320].

    SOURCE: Filed August 20, 1969; amended at 7 Ill. Reg. 4245, effective March 24, 1983; emergency amendment at 7 Ill. Reg. 7328, effective May 31, 1983, for a maximum of 150 days; amended at 7 Ill. Reg. 13930, effective October 12, 1983; codified at 8 Ill. Reg. 19993; amended at 8 Ill. Reg. 24621, effective December 12, 1984; amended at 9 Ill. Reg. 13340, effective August 21, 1985; amended at 10 Ill. Reg. 7862, effective May 16, 1986; amended at 11 Ill. Reg. 9278, effective April 30, 1987; amended at 14 Ill. Reg. 1385, effective January 10, 1990; Part repealed, new Part adopted at 17 Ill. Reg. 21516, effective December 1, 1993; emergency amendment at 18 Ill. Reg. 14444, effective September 1, 1994, for a maximum of 150 days; emergency expired January 28, 1995; amended at 22 Ill. Reg. 21540, effective December 1, 1998; amended at 28 Ill. Reg. 4215, effective February 18, 2004; amended at 29 Ill. Reg. 5713, effective April 8, 2005; amended at 38 Ill. Reg. 9940, effective April 24, 2014.

    SUBPART A: DEFINITIONS AND GENERAL PROVISIONS

    SUBPART B: PLUMBING MATERIALS

    SUBPART C: JOINTS AND CONNECTIONS

    SUBPART D: TRAPS AND CLEANOUTS

    SUBPART E: INTERCEPTORS - SEPARATORS AND BACKWATER VALVES

    SUBPART F: PLUMBING FIXTURES

    SUBPART G: HANGERS, ANCHORS AND SUPPORTS

    SUBPART H: INDIRECT WASTE PIPING, SPECIAL WASTE

    SUBPART I: WATER SUPPLY AND DISTRIBUTION

    SUBPART J: DRAINAGE SYSTEM

    SUBPART K: VENTS AND VENTING

    SUBPART L: PLUMBING SYSTEMS/CORRECTIONAL FACILITIES

    SUBPART M: INSPECTIONS, TESTS, MAINTENANCE AND ADMINISTRATION


    Section 890.APPENDIX B   Illustrations for Subpart A

    B-A

    Section 890.ILLUSTRATION A   Air Gap Drawing #1

     

    (Referenced in Section 890.120, Definition of "Air Gap.")

     

     


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION B   Air Gap Drawing #2

     

    (Referenced in Section 890.120, Definition of "Air Gap.")

     

    B-B


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION C   Battery of Fixtures

     

    (Referenced in Section 890.120, Definition of "Battery of Fixtures.")

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION D   Branch

     

    (Referenced in Section 890.120, Definition of "Branch.")

    B-D

     


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION E   Branch Vent

     

    (Referenced in Section 890.120, Definition of “Branch Vent.”)

     

    B-E


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION F   Building Drain

     

    (Referenced in Section 890.120, Definition of "Building Drain.")

     

    B-F


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION G   Building Sub-Drain

     

    (Referenced in Section 890.120, Definition of "Building Sub-Drain.")

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION H   Circuit Vent

     

    (Referenced in Section 890.120, Definition of "Circuit Vent.")

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION I   Common Vent

     

    (Referenced in Section 890.120, Definition of "Common Vent.")

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION J   Continuous Vent

     

    (Referenced in Section 890.120, Definition of "Continuous Vent.")

     

    B-J


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION K   Dead End

     

    (Referenced in Section 890.120, Definition of "Dead End.")

    B-K

     


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION L   Drain

     

    (Referenced in Section 890.120, Definition of "Drain.")

     

    B-L,B-L


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION M   Fixture Drain

     

    (Referenced in Section 890.120, Definition of "Fixture Drain.")

     

    B-M


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION N   Flush Valve (Repealed)

     

    (Source:  Repealed at 28 Ill. Reg. 4215, effective February 18, 2004)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION O   Grade

     

    (Referenced in Section 890.120, Definition of "Grade.")

     

    B-O


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION P   Horizontal Branch

     

    (Referenced in Section 890.120, Definition of "Horizontal Branch.")

     

    B-P


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION Q   Main Vent

     

    (Referenced in Section 890.120, Definition of "Main Vent.")

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION R   Quarter Bend (Repealed)

     

    (Source:  Repealed at 28 Ill. Reg. 4215, effective February 18, 2004)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION S   Relief Vent

     

    (Referenced in Section 890.120, Definition of "Relief Vent.")

     

    B-S


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION T   Return Offset (Repealed)

     

    (Source:  Repealed at 28 Ill. Reg. 4215, effective February 18, 2004)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION U   Revent Pipe

     

    (Referenced in Section 890.120, Definition of "Revent Pipe.")

    B-U

     


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION V   Stack Vent

     

    (Referenced in Section 890.120, Definition of "Stack Vent.")

     

    B-V


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION W   Trap

     

    (Referenced in Section 890.120, Definition of "Trap.")

    (Referenced in Section 890.120, Definition of "Trap Seal.")

     

    B-W


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION X   Vent Stack (Repealed)

     

    (Source:  Repealed at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION Y   Wet Vent

     

    (Referenced in Section 890.120, Definition of "Wet Vent.")

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION Z   Yoke Vent<br> Section 890.ILLUSTRATION AA   Sleeves<br> Section 890.ILLUSTRATION BB   Buried Piping Parallel to Footing<br> Section 890.ILLUSTRATION CC   Individual Dry Vent

     

    (Referenced in Section 890.120, Definition of "Yoke Vent.")

    B-Z

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)

     


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION AA   Sleeves

     

    (Referenced in Section 890.180(c) and (d))

     

    B-AA

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION BB   Buried Piping Parallel to Footing

     

    (Referenced in Section 890.180(e) and (f))

     

     

    (Source:  Added at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX B   Illustrations for Subpart A

     

    Section 890.ILLUSTRATION CC   Individual Dry Vent

     

    (Referenced in Section 890.120, Definition of "Individual Dry Vent.")

    (Source:  Added at 38 Ill. Reg. 9940, effective April 24, 2014)

     


    Section 890.APPENDIX C   Illustrations for Subpart C

     

    Section 890.ILLUSTRATION A   Caulked Joints

     

    (Referenced in Section 890.320(a))

     

     


    Section 890.APPENDIX C   Illustrations for Subpart C

     

    Section 890.ILLUSTRATION B   Flared Joints

     

    (Referenced in Section 890.320(e))

     

     


    Section 890.APPENDIX C   Illustrations for Subpart C

     

    Section 890.ILLUSTRATION C   Positions of Application for Compression Type Joints

     

    (Referenced in Section 890.320(o)(1))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX D   Illustrations for Subpart D

     

    Section 890.ILLUSTRATION A   Fixture Traps

     

    (Referenced in Section 890.410(a))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX D   Illustrations for Subpart D

     

    Section 890.ILLUSTRATION B   Distance of Trap to Fixture

     

    (Referenced in Section 890.410(b))

     


    Section 890.APPENDIX D   Illustrations for Subpart D

     

    Section 890.ILLUSTRATION C   Types of Traps

     

    (Referenced in Section 890.410(d))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX D   Illustrations for Subpart D

     

    Section 890.ILLUSTRATION D   Trap Cleanouts

     

    (Referenced in Section 890.410(g))

     


    Section 890.APPENDIX D   Illustrations for Subpart D

     

    Section 890.ILLUSTRATION E   Prohibited Traps

     

    (Referenced in Section 890.410(k))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX D   Illustrations for Subpart D

     

    Section 890.ILLUSTRATION F   Underground Drainage

     

    (Referenced in Section 890.420(c))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX D   Illustrations for Subpart D

     

    Section 890.ILLUSTRATION G   Concealed Piping

     

    (Referenced in Section 890.420(d))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX D   Illustrations for Subpart D

     

    Section 890.ILLUSTRATION H   Cleanout Clearance

     

    (Referenced in Section 890.420(j))

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX E   Illustrations for Subpart E

     

    Section 890.ILLUSTRATION A   Grease Interceptor

     

    (Referenced in Section 890.510)

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX E   Illustrations for Subpart E

     

    Section 890.ILLUSTRATION B   Typical Grease Interceptor/Catch Basin

     

    (Referenced in Section 890.510)


     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX E   Illustrations for Subpart E

     

    Section 890.ILLUSTRATION C   Interceptor/Separator Vents

     

    (Referenced in Section 890.510(a)(6))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX E   Illustrations for Subpart E

     

    Section 890.ILLUSTRATION D   Interceptors for Bottling Plants (Repealed)

     

    (Source:  Repealed at 28 Ill. Reg. 4215, effective February 18, 2004)


    Section 890.APPENDIX E  Illustrations for Subpart E

     

    Section 890.ILLUSTRATION E  Laundry Interceptors (Repealed)

     

    (Source:  Repealed at 29 Ill. Reg. 5713, effective April 8, 2005)


    Section 890.APPENDIX E  Illustrations for Subpart E

     

    Section 890.ILLUSTRATION F  Backwater Valve Location (Repealed)

     

    (Source:  Repealed at 29 Ill. Reg. 5713, effective April 8, 2005)


    Section 890.APPENDIX F   Illustrations for Subpart F

     

    Section 890.ILLUSTRATION A   Prohibited Fixtures

     

    (Referenced in Section 890.650(j)

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX F   Illustrations for Subpart F

     

    Section 890.ILLUSTRATION B   Circular Wash Sinks

     

    (Referenced in Section 890.680(d))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX F   Illustrations for Subpart F

     

    Section 890.ILLUSTRATION C   Commercial Type Grinder #1  (Repealed)

     

    (Source:  Repealed at 28 Ill. Reg. 4215, effective February 18, 2004)


    Section 890.APPENDIX F   Illustrations for Subpart F

     

    Section 890.ILLUSTRATION D   Commercial-Type Grinder

     

    (Referenced in Section 890.710(b))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX F   Illustrations for Subpart F

     

    Section 890.ILLUSTRATION E   Protective Guard

     

    (Referenced in Section 890.720(a))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX F   Illustrations for Subpart F

     

    Section 890.ILLUSTRATION F   Trap and Strainer

     

    (Referenced in Section 890.730)

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX G   Illustrations for Subpart G

     

    Section 890.ILLUSTRATION A   Cast Iron Soil Pipe Support #1

     

    (Referenced in Section 890.920)

     


    Section 890.APPENDIX G   Illustrations for Subpart G

     

    Section 890.ILLUSTRATION B   Cast Iron Soil Pipe Support #2

     

    (Referenced in Section 890.920)

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX G   Illustrations for Subpart G

     

    Section 890.ILLUSTRATION C   Horizontal Piping Support (Repealed)

     

    (Source:  Repealed at 28 Ill. Reg. 4215, effective February 18, 2004)


    Section 890.APPENDIX G   Illustration for Subpart G

     

    Section 890.ILLUSTRATION D   Cast Iron Soil Support Stack (Repealed)

     

    (Source:  Repealed at 28 Ill. Reg. 4215, effective February 18, 2004)


    Section 890.APPENDIX H   Illustrations for Subpart H

     

    Section 890.ILLUSTRATION A   Indirect Waste Piping #1

     

    (Referenced in Section 890.1010(a))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX H   Illustrations for Subpart H

     

    Section 890.ILLUSTRATION B   Indirect Waste Piping #2

     

    (Referenced in Section 890.1010(a))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX H   Illustrations for Subpart H

     

    Section 890.ILLUSTRATION C   Indirect Waste Piping #3

     

    (Referenced in Section 890.1010(a))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX H   Illustrations for Subpart H

     

    Section 890.ILLUSTRATION D   Indirect Waste Piping #4

     

    (Referenced in Section 890.1010(a))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX H   Illustrations for Subpart H

     

    Section 890.ILLUSTRATION E   Indirect Waste Connection

     

    (Referenced in Section 890.1010(b))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX H   Illustrations for Subpart H

     

    Section 890.ILLUSTRATION F   Air Gaps

     

    (Referenced in Section 890.1040)

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION A   Cross-Connection #1

     

    (Referenced in Section 890.1130(a))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION B   Cross-Connection #2

     

    (Referenced in Section 890.1130(a))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION C   Cross-Connection #3

     

    (Referenced in Section 890.1130(a))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION D   Flushometer Valve

     

    (Referenced in Section 890.1140(b))

     

     


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION E   Underground Water Piping #1

     

    (Referenced in Section 890.1150(a)(1))

     


     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION F   Underground Water Piping #2

     

    (Referenced in Section 890.1150(a)(2))

     

     


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION G   Underground Water Piping #3

     

    (Referenced in Section 890.1150(b)(2))

     

     


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION H   Water Supply Control

     

    (Referenced in Section 890.1190(a) & (b))


     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION I   Shut-Off Valve at Meter

     

    (Referenced in Section 890.1190(b))

     


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION J   Separate Controls for Each Family Unit

     

    (Referenced in Section 890.1190(e))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


     Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION K   Shut-Off Valves in Buildings Other Than Dwellings

     

    (Referenced in Section 890.1190(f))

     


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION L   Typical Gas Water Heater

     

    (Referenced in Section 890.1220(a))

     


     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION M   Typical Electric Water Heater

     

    (Referenced in Section 890.1220(a))

     


    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION N   P & T Valve Installed in Hot Outlet Line

     

    (Referenced in Section 890.1230(c)(2))


     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX I   Illustrations for Subpart I

     

    Section 890.ILLUSTRATION O   P & T Relief Valve

     

    (Referenced in Section 890.1230(c)(2))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION A   Dead Ends

     

    (Referenced in Section 890.1320(d))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION B   Horizontal to Vertical Change of Direction

     

    (Referenced in Section 890.1320(i))

     


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION C   Horizontal to Horizontal Change of Direction

     

    (Referenced in Section 890.1320(i))

     

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION D   Vertical to Horizontal Change of Direction

     

    (Referenced in Section 890.1320(i))

     

     


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION E   Fixture Connections

     

    (Referenced in Section 890.1320(l))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION F   Waste Stacks

     

    (Referenced in Section 890.1340(d))

     

     


    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION G   Offsets on Drainage Piping

     

    (Referenced in Section 890.1350(a))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)

     


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION H   Relief Vent

     

    (Referenced in Section 890.1350(b)(4))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION I   Above Highest Branch

     

    (Referenced in Section 890.1350(c))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION J   Below Lowest Branch

     

    (Referenced in Section 890.1350(d))

     

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)

     


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION K   Drainage Below Sewer Level

     

    (Referenced in Section 890.1360(a)(1))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX J   Illustrations for Subpart J

     

    Section 890.ILLUSTRATION L   Sanitary Wastes Below Sewer (Repealed)

     

    (Source:  Repealed at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION A   Installation of Vent Stack or Main Vent

     

    (Referenced in Section 890.1420(b))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION B   Vent Terminal

     

    (Referenced in Section 890.1430(a))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION C   Main Vent

     

    (Referenced in Section 890.1420(c))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION D   Roof Extensions

     

    (Referenced in Section 890.1430(b))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION E   Location of Vent Terminal

     

    (Referenced in Section 890.1430(d))

     

     


    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION F   Vent Grade and Vertical Rise

     

    (Referenced in Section 890.1450(a) and (b))


     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION G   Vertical Rise

     

    (Referenced in Section 890.1450(b))

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION H   Height Above Fixtures

     

    (Referenced in Section 890.1450(c))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION I   Heel or Side Inlet

     

    (Referenced in Section 890.1450(d))

     

     


    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION J   Heel or Side-Inlet (Repealed)

     

    (Source:  Repealed at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION K   Fixtures Back-to-Back and Side-by-Side (Repealed)

     

    (Source:  Repealed at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION L   Distance from Trap to Vent

     

    (Referenced in Section 890.1470(a))

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION M   Trap Vent

     

    (Referenced in Section 890.1470(c))

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION N   Trap Weir/Hydraulic Gradient

     

    (Referenced in Section 890.1470(b) and (d))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION O   Common Vent

     

    (Referenced in Section 890.1480(b))


     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION P   Vertical Wet Vent

     

    (Referenced in Section 890.1500(c))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION Q   Horizontal Wet Vent

     

    (Referenced in Section 890.1500(d))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION R   Vertical/Horizontal Wet Vent

     

    (Referenced in Section 890.1500(e))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION S   Single Bathroom Group Venting

     

    (Referenced in Section 890.1500(f)(2))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION T   Bathroom Group Back to Back

     

    (Referenced in Section 890.1500(g)(1) through (4))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION U   Bathroom Groups – Plan

     

    (Referenced in Section 890.1500(h)(3))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION V   Bathroom Groups – Elevation

     

    (Referenced in Section 890.1500(h)(3))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION W   One Bathroom Group – Plan

     

    (Referenced in Section 890.1500(j)(3))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION X   One Bathroom Group – Elevation (Repealed)

     

    (Source:  Repealed at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION Y   Battery Venting

     

    (Referenced in Section 890.1520(a) and (e))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION Z   Dual Branches <br> Section 890.ILLUSTRATION AA   Right and Wrong Vent Connections<br> Section 890.ILLUSTRATION BB   Fixtures Back-to-Back in Battery<br> Section 890.ILLUSTRATION CC   Fixture Connections-Offset Vents<br> Section 890.ILLUSTRATION DD   Circuit Vented Fixtures<br> Section 890.ILLUSTRATION EE   Vent Stacks<br> Section 890.ILLUSTRATION FF   Combination Waste and Vent<br> Section 890.ILLUSTRATION GG   Special Venting for Island Fixtures

     

    (Referenced in Section 890.1520(b))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION AA   Right and Wrong Vent Connections

     

    (Referenced in Sections 890.1450(b) and 890.1520(c))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION BB   Fixtures Back-to-Back in Battery

     

    (Referenced in Section 890.1520(d))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION CC   Fixture Connections-Offset Vents

     

    (Referenced in Sections 890.1520(e) & 890.1550(a))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION DD   Circuit Vented Fixtures

     

    (Referenced in Section 890.1520(f))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION EE   Vent Stacks

     

    (Referenced in Section 890.1450(e))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION FF   Combination Waste and Vent

     

    (Referenced in Section 890.1590(d))

     

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)


    Section 890.APPENDIX K   Illustrations for Subpart K

     

    Section 890.ILLUSTRATION GG   Special Venting for Island Fixtures

     

    (Referenced in Section 890.1600(b))

     

     

    (Source:  Amended at 38 Ill. Reg. 9940, effective April 24, 2014)