TITLE 92: TRANSPORTATION
CHAPTER III: ILLINOIS COMMERCE COMMISSION
SUBCHAPTER c: RAIL CARRIERS
PART 1500 MINIMUM CLEARANCES APPLICABLE TO TRACKS, STRUCTURES, FIXTURES AND OTHER APPURTENANCES OF RAILROADS
SECTION 1500.230 SWITCH STANDS


 

Section 1500.230  Switch Stands

 

a)         Main Tracks.  Main track switch stands exceeding 2 feet 10 inches in height and not exceeding 4 feet in height shall have horizontal clearances of not less than 8 feet from the centerline of an adjacent track to the nearest part of the switch stand above the base of rail; and not less than 8 feet 3 inches when the switch stand exceeds 4 feet in height.

 

b)         Subsidiary Tracks.  Subsidiary track switch stands exceeding 2 feet 10 inches in height and not exceeding 4 feet in height shall be not less than 7½ feet from the centerline of an adjacent track to the nearest part of the switch stand above the base of rail; and not less than 8 feet when the switch stand exceeds 4 feet in height.

 

(Source:  Amended at 29 Ill. Reg. 20360, effective December 15, 2005)