TITLE 41: FIRE PROTECTION
CHAPTER I: OFFICE OF THE STATE FIRE MARSHAL
PART 174 GENERAL REQUIREMENTS FOR UNDERGROUND STORAGE TANKS AND THE STORAGE, TRANSPORTATION, SALE AND USE OF PETROLEUM AND OTHER REGULATED SUBSTANCES
SECTION 174.210 INCORPORATIONS BY REFERENCE


 

Section 174.210  Incorporations by Reference

 

If a UST was installed prior to adoption of these standards, the standard that shall apply to any maintenance or repair shall be the standard cited in this Section unless otherwise specified in 41 Ill. Adm. Code 174, 175, 176 or 177. If a UST or a component of the system is installed, replaced or upgraded, the installation, replacement or upgrade shall comply with the standards listed in this Section.

 

a)         The following publications are incorporated by reference and apply to 41 Ill. Adm. Code 174, 175, 176, and 177:

 

American Petroleum Institute (API). Available from the American Petroleum Institute, 1220 L Street, N.W., Washington D.C. 20005, (202)682-8000:

 

API Recommended Practice 1604, "Removal and Disposal of Used Underground Petroleum Storage Tanks", Third Edition, 1996.

 

API Recommended Practice 1631, "Interior Lining of Underground Storage Tanks", Fifth Edition, 2001.

 

API Standard 2015, "Requirements for Safe Entry and Cleaning of Petroleum Storage Tanks", Sixth Edition, 2001.

 

American Society for Testing and Materials (ASTM). Available from the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken PA 19428-2959, (610) 832-9500:

 

ASTM F 852-08, "Standard Specification for Portable Kerosene and Diesel Containers for Consumer Use" (2008 Edition).

 

ASTM F 976-08, "Standard Specification for Portable Gasoline Containers for Consumer Use" (2008 Edition).

 

The ICC International Building Code. Available from ICC, 4051 W. Flossmoor Rd., Country Club Hills IL 60477-5795, (708)799-2300:

 

ICC Building Code (2009).

 

NACE International. Available from NACE International, 1440 S. Creek Dr., Houston TX 77084, (281)228-6223:

 

NACE Standard Practice SP0169, Control of External Corrosion on Underground or Submerged Metallic Piping Systems (2007 Edition).

 

NACE Standard Recommended Practice RP0285, Corrosion Control of Underground Storage Tank Systems by Cathodic Protection (2002 Edition).

 

National Fire Protection Association (NFPA). Available from the National Fire Protection Association, 1 Batterymarch Park, Quincy MA 02269, (617)770-3000 or (800)344-3555:

 

NFPA 10, "Standard for Portable Fire Extinguishers" (2007).

 

NFPA 13, "Standard for the Installation of Sprinkler Systems" (1983).

 

NFPA 17, "Standard for Dry Chemical Extinguishing Systems" (2009).

 

NFPA 72, "National Fire Alarm Code" (2010).

 

NFPA 30, "Flammable and Combustible Liquids Code" (2008). Also available from ANSI.

 

NFPA 30A, "Automotive and Marine Service Station Code" (2008). Also available from ANSI.

 

NFPA 58, "Liquefied Petroleum Gas Code" (2008).

 

NFPA 70, "National Electrical Code" (2008). Also available from ANSI.

 

NFPA 101, "Life Safety Code" (2000). Also available from ANSI.

 

NFPA 385, "Tank Vehicles for Flammable and Combustible Liquids" (2007). Also available from ANSI.

 

National Leak Prevention Association (NLPA). Available from the National Leak Prevention Association, 75-4 Main Street, Suite 300, Plymouth NH 03264, info@NLPA-online.org, (815)301-2785 (phone), (240)757-0211 (fax):

 

NLPA Standard 631 (Chapters A & B Only), "Entry, Cleaning, Interior Inspection, Repair and Lining of Underground Storage Tanks" (Chapter A) and "Future Internal Inspection Requirements of Lined Tanks" (Chapter B), Third Edition, 1991.

 

National Work Group on Leak Detector Evaluations (NWGLDE), List of Leak Detection Evaluations for Storage Tank Systems, Sixteenth Edition (January 12, 2009), available at www.nglde.org.

 

Steel Tank Institute (STI). Available from the Steel Tank Institute, 944 Donata Court, Lake Zurich IL 60047, (847)438-8265:

 

STI (F894.01) (ACT 100), "Specification for External Corrosion Protection of FRP Composite Steel Underground Storage Tanks", revised January 2009.  Underwriter Laboratories, c/o COMM 2000, 151 Eastern Avenue, Bensenville IL  60106, 1-888-853-3503:

 

Pre-Engineered Dry Chemical Extinguishing System Units, UL 1254 (2005).

 

b)         The following federal regulations (Code of Federal Regulations (CFR)) are incorporated by reference and apply to 41 Ill. Adm. Code 174, 175, 176 and 177. Available from the Superintendent of Documents, U.S. Government Printing Office, Washington D.C. 20401, (202)512-1800:

 

29 CFR 1926 (July 15, 2002)

 

40 CFR 280 (September 7, 1995)

 

40 CFR 302.1 through 302.6 and 355.40 (December 18, 2008).

 

c)         If the above-referenced publications conflict with specific provisions of 41 Ill. Adm. Code 174, 175, 176 or 177, the Illinois rules shall take precedence over the publications identified in subsection (a) and the federal rules (identified in subsection (b)) shall take precedence over the Illinois rules. However, the provisions of 41 Ill. Adm. Code 174, 175, 176, and 177 shall not be deemed to be in conflict with federal rules on the basis that the Illinois rules are more specific than, more stringent than, or impose requirements for which no similar requirements are contained in, laws and rules enforced by agencies of the federal government.

 

d)         The following Illinois regulations are referenced in this Part:  

 

Pollution Control Board:  35 Ill. Adm. Code 734, 742 and 750.410

 

Department of Transportation:  92 Ill. Adm. Code 172